INT Range
INT400 High level sounder only
INT500 High and low level sounder plus strobe
INT600 High and low level sounder
High and low level sounder functions are triggered independently for alarm notification and entry/exit tones as required; low level sounder is fitted with a volume control which can be set to individual requirements.
| 400(S) | 500(S) | 600(S) | |
|---|---|---|---|
| Grade | 3 | 3 | 3 |
| Environmental Class | II | II | II |
| Siren Output (dbA/1m) | 120 | 120 | 120 |
| Exit Tone Output (db) | N/A | 80 | 80 |
| Operating Voltage | 12V - dc | 12V - dc | 12V - dc |
| Siren Operating Current | 260mA | 260mA | 260mA |
| Exit Tone Current | N/A | 80mA | 80mA |
| Strobe Operating current | N/A | 100mA | N/A |
| Quiescent Current | 15(19)mA | 15(19)mA | 15(19)mA |
| Cut Off Timer | 15 min | 15 min | 15 min |
| Battery 'S' Versions | 6v/150mA NiMH | 6v/150mA NiMH | 6v/150mA NiMH |
| Replaceable Battery 'S' Versions | Yes | Yes | Yes |
| Siren Trigger | Neg | Neg | Neg |
| Exit Tone Trigger | N/A | Neg | Neg |
| Strobe Trigger | N/A | Neg | N/A |
| Strobe Flash Rate | N/A | 1/sec | N/A |
| Tamper Detection | Cover/Rear | Cover/Rear | Cover/Rear |
| Tamper Signal | Neg | Neg | Neg |
| SAB/SCB 'S' Versions | SAB | SAB | SAB |
| Cover & Backplate | 3mm Polycarbonate | 3mm Polycarbonate | 3mm Polycarbonate |
| Dimensions | 110W x 160H x 40D | 110W x 160H x 40D | 110W x 160H x 40D |
| Screen Printing Available | Yes | N/A | Yes |