External Sounders
Internal Sounders
Power Supply Units
Magnetic Contacts
Shock Sensors
Ancillaries
EN Range
The EN range of power supplies has been specifically designed to provide a comprehensive and flexible range for engineers designing Intruder Alarm Systems to grade 2 and 3 under PD6662:2004 / EN50131, with built in quality and reliability.
The Range Consists of Nine Models:
Grade 2:
- EN2-07-A
- EN2-07-B
- EN2-17-B
- EN2-17-C
Grade 3:
- EN3-07-A
- EN3-07-B
- EN3-17-B
- EN3-17-C
- EN3-34-R
EN Features:
- Comprehensive Battery
Management
- Deep Discharge Protection
- Battery Fault Detection (grade 3)
- High Efficiency 3 Stage Charging (17Ah)
- Double Battery Model has independent Battery Charging & Monitoring
- Dedicated Fault
Outputs
- EPS Fault (mains fail)
- APS Fault (battery fault) (grade 3)
- PSU Fault (general fault)
- Internal LED PSU Status
- High Security Front and Rear Tamper (grade 2 front only)
- Full Rated Current To Load + Battery Charging
- Electronic Overload Protection
- Mains Transient Protection
| Output (mains on) | 13.8V dc nominal | ||
| Load Output | 07
Maximum 1.0A
12 hours - 580/660mA 17 Maximum 1.5A 12 hours - 1.4/1.5A 34 Maximum 3.0A 12 hours - 2.8/3.0A |
||
| Mains Supply | 230V +10%/-15%@50Hz | ||
| Environment | -10C to 40C @ 95%RH | ||
| Enclosure | |||
| Type A | 200Hx230Wx80D - hinge lid | ||
| Type B | 330Hx355Wx80D - clam lid* | ||
| Type C | 275Hx330Wx80D - hinge lid | ||
| Type R | 410Hx390Wx90D - clam lid | ||
| Box Sizes for battery | |||
| '07' models | 1 x 7 or 8Ah 1.0A** | ||
| '17' models | 1 x 17 or 18Ah 1.5A** | ||
| '34' models | 2 x 17 or 18 Ah 3.0A** | ||
| *Communication devices can be
accommodated in a 'B' size box when used with a 7 or 8Ah
battery. **Full current to load plus additional current to charge standby battery |
|||
| EN range Complies with the following standards | |||
|---|---|---|---|
| Grade (EN50131) EN2 – Grade 2 EN3 – Grade 3 Environmental Class II |