EN Range

The EN range of power supplies has been specifically designed to provide a comprehensive and flexible range for engineers designing Intruder Alarm Systems to grade 2 and 3 under PD6662:2004 / EN50131, with built in quality and reliability.

Elmdene Fire and Security products

The Range Consists of Nine Models:

Grade 2:

  • EN2-07-A
  • EN2-07-B
  • EN2-17-B
  • EN2-17-C

Grade 3:

  • EN3-07-A
  • EN3-07-B
  • EN3-17-B
  • EN3-17-C
  • EN3-34-R

EN Features:

  • Comprehensive Battery Management
    • Deep Discharge Protection
    • Battery Fault Detection (grade 3)
    • High Efficiency 3 Stage Charging (17Ah)
    • Double Battery Model has independent Battery Charging & Monitoring
  • Dedicated Fault Outputs
    • EPS Fault (mains fail)
    • APS Fault (battery fault) (grade 3)
    • PSU Fault (general fault)
  • Internal LED PSU Status
  • High Security Front and Rear Tamper (grade 2 front only)
  • Full Rated Current To Load + Battery Charging
  • Electronic Overload Protection
  • Mains Transient Protection
Elmdene Fire and Security products
Output (mains on) 13.8V dc nominal
Load Output 07 Maximum 1.0A 12 hours - 580/660mA
17 Maximum 1.5A 12 hours - 1.4/1.5A
34 Maximum 3.0A 12 hours - 2.8/3.0A
Mains Supply 230V +10%/-15%@50Hz
Environment -10C to 40C @ 95%RH
Enclosure
Type A200Hx230Wx80D - hinge lid
Type B 330Hx355Wx80D - clam lid*
Type C275Hx330Wx80D - hinge lid
Type R410Hx390Wx90D - clam lid
Box Sizes for battery
'07' models 1 x 7 or 8Ah 1.0A**
'17' models 1 x 17 or 18Ah 1.5A**
'34' models 2 x 17 or 18 Ah 3.0A**
*Communication devices can be accommodated in a 'B' size box when used with a 7 or 8Ah battery.
**Full current to load plus additional current to charge standby battery
EN range Complies with the following standards
Grade (EN50131) EN2 – Grade 2 EN3 – Grade 3 Environmental Class II